Home Rental Product for Utah Medical Liberty Pelvic Floor Electrical Stimulators

PFS-200
Liberty Pelvic Floor Electrical Stimulator.
Requires one of the exercisers below.
$60.00 monthly rental fee
All rental fees go toward purchase price of $375.00
![librtyp1[1] librtyp1[1]](https://www.currenttechnologyinc.com/wp-content/uploads/2020/09/librtyp11.jpeg)
PFS-041
Liberty Vaginal Exerciser
$75.00
![librtyp2[1] librtyp2[1]](https://www.currenttechnologyinc.com/wp-content/uploads/2020/09/librtyp21.jpeg)
PFS-042
Liberty Extended Handle Vaginal Exerciser
$75.00
![librtyp3[1] librtyp3[1]](https://www.currenttechnologyinc.com/wp-content/uploads/2020/09/librtyp31.jpeg)
PFS-043
Liberty Rectal Rectal Exerciser
$75.00
Federal Law (USA) restricts this device to sale by or on the order of a physician (or licensed practitioner).
PATIENT SELECTION CRITERIA
Indications:
-
Urge Incontinence due to detrusor instability or of idiopathic origin
-
Stress Incontinence, not associated with intrinsic sphincter deficiency
-
Mixed Incontinence
-
Willingness to comply with the therapy plan
-
Ability of patient to demonstrate understanding of the use of the Liberty System
-
Good Physical Health
Contraindications:
-
Neurological deficiency that would not permit proper sensory perception or stimulation
-
Currently Pregnant or attempting to get pregnant
-
Cardiac pacemaker, or a history of rate or conductive disturbances
-
Anatomical vaginal or rectal structure that does not permit proper and complete placement of the exerciser. In the case of vaginal stenosis, the small Rectal Exerciser may be inserted vaginally.
-
Irregular menstrual bleeding cycles
-
Urinary or vaginal infections, localized lesions, or other undiagnosed symptoms
-
History of urinary retention, or current symptoms
LIBERTY® PRODUCT FEATURES:
-
Channel switch - permits selection for either stress (50Hz) or urge (12.5Hz) Incontinence
-
The stress mode is associated with strengthening and toning the pelvic floor muscles.
-
The urge mode stimulates the detrusor inhibitory reflex. Mixed incontinence can be treated by alternating channels with each treatment.
-
-
Intensity adjustment knob - controls the intensity of stimulation from zero to 65mA. This is adjusted for each individual patient.
-
Continuous control button - when depressed will deliver uninterrupted stimulation while determining the appropriate intensity level.
-
Indicator light - illuminates when the device is delivering stimulation.
-
Duty cycle - is the duration of the stimulation cycle and rest cycle. It is preset at 5/10 (5 seconds of stimulation and 1 seconds of rest).
-
Duration - of treatment is prescribed by the clinician. Liberty® will automatically shut off after 30 minutes. If a shorter treatment time is desired, the device can be turned off by turning the intensity adjustment knob to zero.
Liberty® PFS therapy may be appropriate for you if:
-
You have good general health both mentally and physically.
-
You experience stress incontinence not associated with intrinsic sphincter deficiency.
-
You experience urge incontinence due to detrusor instability or of idiopathic (unknown) origin.
-
You experience mixed incontinence.
-
You have normal menstrual cycles and are not pregnant or attempting to get pregnant.
-
Your vagina is anatomically normal and free of any infections or lesions.
-
You do not have a cardiac pacemaker or a history of abnormal heart rhythm or conductive disturbances.
-
You do not have a history of urinary retention or current symptoms.
-
Your nervous system permits you to accurately feel the level of electrostimulation.
-
You are able to understand and demonstrate understanding of the use of the Liberty® System.
Suggested Treatment Protocols:
15 minutes, twice a day, every other day treatments are as effective as every day treatments, assuming patient compliance. Following cure or improvement, a maintenance program of 2-3 treatments per week should be implemented. Mixed incontinence can be treated by alternating channels with each treatment. Improvements from Pelvic Floor Stimulation treatments are typically as follows:
Reduced Symptoms
Significant Improvement or Cure
Objective Cure
Objective (>50%)
Improvement
Detrusor
Instability
Genuine Stress
Incontinence
2 - 3 Weeks
6 - 8 Weeks
3 Months
3 - 6 Months
43-49%1-2
39-45%7-8
69-77%3-6
62-70%7-9
1Brubaker, L. (1997) 2Primus, G. (1996)
3Siegel, S.W. (1997) 4Smith, J.J. (1996)
5Caputo,R.M. (1993) 6Zollner-Nielson (1992)
7Yamanishi, T. (1997) 8Richardson, D.A (1995)
9Sand, P.K.(1995)
-
Output Current: 0-65mA Symmetrical Biphasic
-
Pulse Width: 300 microseconds at 50% peak
-
Power Source: Two 3V lithium batteries
-
Battery Life: 60 hours at 45mA
-
Output Type: Constant current over range of 100 to 100 Ohms
-
Output Isolation: >10 Ohms